HOME Carbon dioxide detector

iCeeO2-700 CO2

CURRENT POSITION:Home >> Product >> Carbon dioxide detector

iCeeO2-700 CO2

【Features】

2-Channel Low Drift NDIR Sensor

Build-In Plant Types Directory

3 color LEDs for Easy-Reading

Foolproof Hold Home function

CRR,  CO2 Replenish Reminder

CO2/Temperature/RH Monitor; Tracer

Chart with variable time Zoom Levels


Instructions Download

iCeeO2-700.pdf

iCeeO2-700(02).pdf

contact details:0123-0000000
Detail

Operating Instructions

Initial Setup : When first unboxing, plug in the unit to the included Micro USB (or one of your own) to almost any cell phone charger or USB power source. If successfully connected, 3 things will happen while booting up:

    image.png3 LEDs flash one by one

    image.pngChart display shows the current software version & “Warm Up”

    image.pngMain display shows a countdown from 10

Once the countdown is complete, your product is ready to use. No initial setup or calibration is needed.

    image.pngimage.png

                         1. Deploy the Stand                                               2.Plug in USB Power Cable


LCD Display

        image.png

                         

1. CO2 Chart 1A.x10 multiplier for ppm reading

2. Max Reading of Chart

3. Indicates what the chart will show: CO2, TEMP or RH

4. Automatic cycle between CO2, RH, and Temperature on the chart

5. Min Reading of Chart

6. Plant or Human mode

7. Audible Alarm On/Off

8. Main Menu                 

9. Temperature Reading

11. RH Reading

12. CO2 Reading

13. Time per Division – indicates the chart’s time per unit division

14. Automatic cycle between zoom levels of time

15. Zoom Level of Time – indicates the chart’s span of time

16. Good Zone Indicator


Trend Chart

The trend chart (1) displays the past readings for any of the three parameters (CO2/Temp/RH). There are 4 modes that can be toggled by using UP key: CO2, TEMP, RH, and Cycle (automatically cycles through CO2/Temp/RH),  as shown below

image.png

 

 

Trend Chart Zoom 

Below is a table that show the available Zoom Levels for all parameters CO2/Temp/RH, as well as the duration of each division for corresponding Zoom Levels:

Zoom Level


  (Time Span) (15)

Time Per


    Division(13)

image.png

1m (minute)

5m/div

1h (hour)

5m/div

1d (day)

2h/div

1w (week)

0.5d/div

Auto Cycle Zoom

Cycle

Using DOWN will toggle the available Zoom Levels for each parameters. Note that in addition to the Zoom Levels for each parameter, there is an option that will automatically cycle between the Zoom Levels. This can be achieved just by pressing DOWN until  icon(14) appears at the bottom left of the chart.

 

Max/Min

At the top right corner of the display, there are two numerical indicators: Max (2)and Min (5). As the Zoom Level is changed, the Max and Min values will reflect the maximum and minimum values on the chart of the selected parameter(CO2; Temp and RH). At startup, the unit will automatically display values for CO2.

 

LED Display


image.png



Specifications

Typical test conditions, unless otherwise specified:  Ambient Temp =23+/-3°C,  RH=50%-70%,  Altitude=0~100 meter

Measurement

Spec

Operating Temperature

32°F to 122°F (0°C to 50°C)

Storage Temperature

-4°F to 140°F (-20°C to 60°C)

Operating & Storage RH

0-95%, non-condensing

CO2 Measurement


Accuracy  at 0~3000ppm

±50ppm or ±5% of reading, whichever is greater

Accuracy  over 3000ppm

±7%

Repeatability

20ppm at 400ppm (standard dev. of 10 readings in 1 minute)

Measurement Range

0-5000ppm

Display Resolution

1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)

Temp Dependence

±0.1% of reading per °C or ±2ppm per °C, whichever   is greater, referenced to 25°C  

Pressure Dependence

0.13% of reading per mmHg (corrected by user’s   altitude input)

Response Time

<2min for 63% of step change or <4.6min for   90% step change

Warm-up Time

<30 sec

Temp Measurement


Operating Temperature

32°F to 122°F (0°C -50°C)

Display Resolution

0.2°F (0.1°C)

Accuracy

±1°F (±0.5°C)

Response Time

<20min (63%)

RH Measurement


Range

0-100%

Accuracy

±5%

Resolution

1% on Main Reading,  0.1% on Max Min Reading



Power Requirements

160mA Peak, 15mA average at 5.0V

Battery Life

Battery is not included.

below is calculation by theory: (reference only, not a guarantee)

For 5000mAh battery, 200Hr/8.3day

Dimension

120*91.2*27mm   (4.7*3.6*1.1inch)

Weight

148g ( 5.22oz)  Device only, AC Adapter not included